Erba Semi Automatic ECL- 105 Single Channel Coagulation Analyzer
Automation
Semi-Automatic
Number Of Chambers
1
Brand
Erba
Model Name/Number
ECL 105
Power Supply
100-240 VAC and 50/60 Hz
Weight
1 kg
Humidity
Max. 80% Relative Humidity, non-condensing
Dimension
216 x 205 x 75 mm
Operating Temperature
17-32 DegreeC
Power Consumption
45 Watts
In-Rush Power
150 VA or less
Country of Origin
Made in India
Product Description:
ECL 105 is a single channel semi automated coagulation analyzer.. It is a small, ergonomically designed unit packed with many advanced features, whose benefits are readily usable by the end-user.
It’s a modern and advanced analyzer in Hemostasis. This single channel coagulation analyzer redefines the benefits in its class Erba. ECL 105 can perform PT, APTT, Fibrinogen, Thrombin Time, All Factiors, Lupus and DDimer.
Product Features:
Clotting Tests such as PT, aPTT, Fibrinogen, Thrombin time, Factors, Lupus anticoagulant performed using Light scatter principle
Tests like D Dimer performed using Immuno-turbidimetry principle
Interactive touch screen interface
Clotting Graph provides details of the clotting testCuvette and reagent management software
Twelve levels of QC with Levy-Jennings Plot- Identifies random and systematic errors
Temperature stability at 37 degree C to perform the tests.
Low Reagent Consumption
USB Connectivity
CE mark
Product Applications:
ECL 105 has uses in various routine IVD labs for doing routine PT and aPTT
It has application in Blood Banks for Quality Control of Fibrinogen and Factor VIII
It is used as Standby to bigger systems, in accredited centres
It is used in Research Facilities to perform PT and aPTT on animal samples such as rat, mouse, rabbit, hamsters etc
Key Specifications:
Single channel semi-automated hemostasis system
It can analyze 1 test at a time
Sample id can be 14 digits alphanumeric, with progressive id or custom id options
It is also possible to have a second position of assay preparation/incubation during the analysis of the current one, using preparation line option
Optically detects and automatically moves to the next assay steps and auto starts the measurements
Tests principles:
Clotting (scattered light at 640nm)
Immuno-turbidimetric (turbidimetry at 800nm)
Calibrations:
Up to 6 calibration levels per assay
Storage of the active calibration curve
Quality Controls:
Up to 12 different control total can be assigned to any given assay
Automatic Levey-Jennings plotting
Automatic statistics calculation
Storage of Quality Control results
Stored Results:
Independent storage allocation in the instrument memory for Quality Control (QC) and patient determinations
Up to 1000 results for QC determinations
Up to 1000 results for patients
New results automatically replace the oldest results of the appropriate category past the maximum storage allowance
Reaction curves are exclusively stored on the external USB pen drive.
Regular backup and file purging is recommended from the USB pen drive to insure rapid operations.
Reviews